INSTALLATION PROCEDURE
Warning! Disconnect AC power from
organ before proceeding
- Remove music rack base assembly, the 4 manual hold down bolts,
and the screws, which attach the lower manual to the front rail.
- Carefully lift and prop up keyboard assembly.
- Mount the Hampton LEQ3A unit under the right or left side
of the front rail using the provided screws. Route both cables
underneath keyboard assembly to the rear of the organ.
- Lower keyboard assembly.
- Disconnect Black and Red wires from GG terminals from organ
pre amp.
- Attach the shield wire from the larger cable assembly to
chassis ground of the organ pre amp.
- Attach the White/Clear wires from the larger cable assembly
to the GG terminals on the organ pre amp.
- Attach the Blue wires from the same cable to the Red and
Black wires previously removed from the organ pre amp. Secure
with wire nuts.
- Mount transformer near the organ pre amp power panel with
screws provided.
- Remove pre amp power panel cover.
- Attach the Brown and Black wires from the transformer to
the Blue and Grey wires on the organ pre amp power panel.
- Attach the Black wire from the smaller cable assembly to
the White wire from the transformer with a wire nut.
- Attach the Green wire from the same cable assembly to the
Red wire from the transformer with a wire nut.
- Attach the Red wire from the same cable assembly to the Red/White
wire from the transformer with a wire nut.
- Replace all bolts, screws, covers, and assemblies previously
removed. Reconnect AC power.
Using the LEQ3A with an unbalanced input and/or
output
When using the Hampton LEQ3A with an unbalance input or output,
simply short the unused wire to ground. You can use the LEQ3A
in any combination. (Balanced in/unbalanced out) (Unbalanced in/balanced
out) (Unbalanced in/unbalanced out) etc.